| Series | FVR-E11S | |||||||||||||
| Output overload capability | 200% of rated current for 0.5s, 150% of rated current for 1min. | |||||||||||||
| Braking torque | Regenerative braking |
| ||||||||||||
| DC injection braking |
| |||||||||||||
| Acceleration/deceleration time | 0.01 to 3600s (Acceleration/deceleration can be set independently.) | |||||||||||||
| Multistep frequency control | 16 steps | |||||||||||||
| Frequency setting signal | 0 to 5V DC, 0 to 10V DC, 4 to 20mA DC | |||||||||||||
| Protective functions | Stall prevention, overcurrent, instantaneous power failure or undervoltage, overvoltage, inverter overheating, external alarm (tripping of external thermal overload relay), motor overload (tripping of electronic thermal overload), CPU error, communications error, output wiring fault, output terminal short-circuit, and ground fault of output terminal at start up | |||||||||||||
| Alarm relay output | SPDT contact | |||||||||||||
| Enclosure and cooling method | Totally enclosed natural cooling type
(IP40)(0.75kW or less) Totally enclosed fan cooling type (IP40, except fan)(1.5 to 7.5kW) | |||||||||||||
|
Rated AC Input
Voltage |
Product
Range | ||||||||||||
|
|
|
Allowable
Variation | |||||||
|
| Series | FRENIC5000G11S | FRENIC5000P11S | |
|---|---|---|---|
| Output overload capability | 200% of rated current for 0.5s 150% of rated current for 1min |
110% of rated current for 1min | |
| Braking torque | Regenerative braking | 150% or more at 3%
ED (0.75kW or less) 100% or more at 5 to 2% ED (1.5 to 7.5kW or less) 20% or more (11 to 22kW) 10 to 15% (30kW or more) |
20% or
more (11 to 22kW) 10 to 15% (30kW or more) |
| DC injection braking | Starting frequency: 0.1 to 60Hz
(adjustable) Braking time: 0 to 30s (adjustable) Braking voltage: 0 to 100% (adjustable) | ||
| Acceleration/deceleration time | 0.01 to
3600s (Acceleration/deceleration can be set independently) | ||
| Multi frequency control | 16 steps | ||
| Frequency setting signal | 0 to ±5V DC, 0 to ±10V DC, 4 to 20mA | ||
| Protective functions | Stall prevention, overcurrent, instantaneous power failure or undervoltage, overvoltage, inverter overheating, external alarm (tripping of external thermal overload relay), motor overload (tripping of electronic thermal overload), communications error, CPU error, memory error, short-circuit, ground fault, blown out fuse, input open-phase protection, output open-phase protection | ||
| Alarm relay output | SPDT contact | ||
| Enclosure and cooling method | Totally enclosed natural cooling type
[IP40] (0.75kW or less) Totally enclosed fan cooling type [IP40, except fan] (1.5 to 2.2kW) Fan cooling type [IP00] (30kW or more) For inverters of 30kW or more, the totally enclosed type [IP20] is optional. |
Totally enclosed fan cooling
type [IP40, except fan] (5.5 to 22kW) Fan cooling type [IP00] (30kW or more) For inverters of 30kW or more, the totally enclosed type [IP20] is optional. | |
|
Rated AC Input
Voltage | |||||||||||||
|
|
Allowable
Variation |
Product
Range | ||||||||||||||
|
|
| Series | FVR-C11S | |
|---|---|---|
| Output overload capability | 150% of rated current for 1min | |
| Braking torque | Regenerative braking | 150% or more (0.1, 0.2kW) 100% or more (0.4, 0.75kW) 50% or more (1.5kW) 30% or more (2.2, 3.7kW) |
| DC injection braking | Starting frequency: 3.0Hz
(Fixed) Braking time: 0.1 to 30s (Adjustable) Braking voltage: 0 to 100% (Adjustable) | |
| Acceleration time | 0.0 to 60s (0.0=0.01s) | |
| Deceleration time | 0.1 to 60s | |
| Multi frequency control | 4 steps | |
| Frequency setting signal | 0 to 5V DC, 0 to 10V DC, 4 to 20mA | |
| Protective functions | Stall prevention, overcurrent, undervoltage, overvoltage, inverter overheating, external alarm (tripping of external thermal overload relay), CPU error, short-circuit, ground fault, surge, motor overload (tripping of electronic thermal overload), inverter overload | |
| Alarm relay output | SPDT contact | |
| Enclosure and cooling method | Natural cooling type [IP20] (0.75kW or less) Fan cooling type [IP20, except fan] (1.5kW or more) | |
|
Rated AC Input
Voltage |
Product
Range | ||||||
|
|
|
Allowable
Variation | ||||||
|